****************************************************************************** From: ui22273@sunmail.lrz-muenchen.de Subject: FAB-HR? Date: Sat, 2 Dec 1995 16:51:42 +0100 Organization: Leibniz-Rechenzentrum, Muenchen (Germany) Hi everybody, I`m working at the University of Munich and am currently experimenting with FAB-HR on a MAT95Q. As our samples work mainly in m-NBA as matrix I use PEG as reference. Does anyone has a exact mass list of the signals, as these are not only PEG Fragments but others with strange differences of 6 or 13 amu? Has someone experiences with PEG as reference? What mmu difference do you think is ok for the confirmation of a sample? Werner Spahl (ui22273@sun1.lrz-muenchen.de) "The meaning of my life is to make me crazy!" ****************************************************************************** Date: Wed, 06 Dec 95 09:46:37 -0500 From: Chip Cody Subject: Re: FAB-HR? Dear Werner, We have a mass listing for PEG on our web page at http://www.jeol.com along with FAB matrix spectra and other reference masses. PEG is generally a very good reference standard for use with NBA as a matrix. You will often see cation adducts (M+Na or M+K) as well as the protonated species. The cations are omnipresent, and probably come from solvents stored in glass, etc. You may see dehydrated species, particularly at low mass. However, I'm not sure about the strange mass differences that you report. There may be impurities present. The mmu difference required to confirm a sample depends a lot on the molecular weight and other information available to you about the sample (isotope ratios, other chemical information, sample history). The higher the mass, the less you can trust the mass measurement to PROVE a composition. However, an accurate mass measurement is always a valuable piece of confirming evidence, and a check against errors in interpretation. For what it's worth, there's an essay on interpreting exact masses on our website. Good luck! Chip Cody Applications Manager Mass Spectrometry JEOL USA, Inc. ****************************************************************************** From: jwindak@umich.edu (Jim Windak) Subject: Re: FAB-HR? Followup-To: sci.techniques.mass-spec Date: 7 Dec 1995 12:35:26 GMT Organization: University of Michigan The main peaks in the PEG spectrum are the protonated oligimers of PEG. They are of the general form (C2.H4.O)nH3O+ , and they differ by 44 amu (the mass of the repeat unit C2.H4.O). I've also observed smaller intensity peaks due to sodium or potassium adducts of the PEG oligimers. These are of the form (C2.H4.O)H2O.Na+ and (C2.H4.O)H2O.K+ . I've never observed peaks that differ by 13 amu, but the 6 amu difference which you observe might possibly be explained by the presence of lithium ion. At times I've observed lithium ion adducts of the form (C2.H4.O)H2O.Li+ . These would differ by 6 amu from the corresponding protonated oligimers. (Subtract 7 amu for Li and add 1 amu for the proton). PEG produces higher intensity peaks if it is run in a 4:1 mixture of dithiothreitol / dithioerythritol which has been melted to form a viscous liquid, rather than running it in m-NBA. Also, the PEG should be diluted about 20:1 with methanol before adding it to the target. If it is too concentrated, the signals will be suppressed. Jim Windak University of Michigan Chemistry Dept. jwindak@umich.edu